Works on medium or high-voltage networks: switching, arc flash, excavation and public roads.

Adapt it to my project (free) Download for Excel (CSV)

Risks35
● Low0
● Moderate15
● High9
● Critical11

Assumptions: Energy / utilities · Execution / works · 20 people · electrical work or work near live installations, site in operation (co-activity with production), excavation, trenches, earthworks, work on or near public roads, work at height (roofs, scaffolding, platforms), night or shift work, mainly outdoors, works during winter.

Ref.RiskScorePreventionProtection
R-001 Fall from height
Cause : Missing or removed guardrails, scaffold not inspected, harness misused
Consequence : Serious injury or death, investigation, site stoppage
25 P5×I5 • Collective protection before any access
• Scaffold handover and daily check
• Rescue-at-height plan
R-002 Electric shock or electrocution
Cause : Work near live parts, incomplete isolation
Consequence : Severe burns, death, fire
20 P4×I5 • Electrical isolation and voltage check
• Up-to-date electrical authorisations
R-003 Worker struck by road traffic
Cause : Insufficient signage, driver speed, poor visibility
Consequence : Serious injury or death, road user accident
20 P4×I5 • Compliant protected temporary signage
• Traffic order and high-visibility clothing
R-004 Heat stroke
Cause : Physical work in full sun, heatwave, insufficient hydration
Consequence : Serious illness, hospitalisation, death
20 P4×I5 • Shifted hours and shaded breaks
• Cool water and buddy checks
R-005 Interference between work and ongoing operations
Cause : Unexpected start-up of installations, production flows not stopped
Consequence : Accident, production stoppage, damage
16 P4×I4 • Work permit issued by the operator
• Direct link with the control room
R-006 Accident during wind turbine work
Cause : Work at height and in confined spaces, difficult evacuation, weather
Consequence : Fall, casualty hard to rescue
15 P3×I5 • Specific training and working in pairs
• Rescue plan and evacuation equipment
R-007 Restart while lockout not properly removed
Cause : Incomplete lockout, poor communication between teams, restart pressure
Consequence : Equipment energised or moving with a worker exposed
15 P3×I5 • Lockout procedure with personal padlocks
• Check before restart
R-008 Prolonged bad weather
Cause : Rain, frost, snow or strong wind during outdoor work
Consequence : Site stoppages, degraded quality (concrete, paint), delay
15 P5×I3 • Season-aware scheduling
• Temporary protection
R-009 Arc flash during high-voltage switching
Cause : Unsuitable equipment, procedure not followed
Consequence : Severe burns, death
15 P3×I5 • Switching procedures and authorised person
• Arc flash protective equipment
R-010 Slip, trip or fall on the same level
Cause : Wet or cluttered floors, cables on the floor, poor lighting, level changes
Consequence : Sprains, fractures, sick leave
15 P5×I3 • Housekeeping and clear walkways
• Lighting and suitable footwear
R-011 Trench or excavation collapse
Cause : No shoring, slopes too steep, waterlogged ground
Consequence : Burial, fatality
15 P3×I5 • Systematic shoring or battering
• Daily excavation inspection
R-012 Unexpected start-up during maintenance
Cause : Residual energy, remote control, controller restarting
Consequence : Crushing, electric shock, entanglement
12 P3×I4 • Isolate all energy sources
• Lockout sheets per machine
R-013 DC electric arc
Cause : Poorly crimped or incompatible connectors, work on energised strings in daylight
Consequence : Burns, fire on the installation
12 P3×I4 • Compatible connectors and checked crimping
• Workers trained for DC
R-014 Thermal runaway in battery storage
Cause : Cell defect, overcharging, failed ventilation or cooling
Consequence : Fire, explosion, toxic gases
12 P3×I4 • Battery management system and monitoring
• Safety distances and fire brigade plan
R-015 Damage to a gas pipeline
Cause : Work nearby without precise location, inaccurate plans
Consequence : Leak, explosion, neighbourhood evacuation
12 P3×I4 • Request plans and hand-dig trial holes
• Emergency procedure for leaks
R-016 Lower profitability than forecast
Cause : Overestimated output, changes to feed-in prices or support schemes, underestimated operating costs
Consequence : Longer payback, difficulty repaying loans
12 P3×I4 • Profitability study with prudent scenarios
• Production monitoring and maintenance
R-017 Historical soil contamination found on an existing site
Cause : Undocumented past activities, forgotten underground tanks
Consequence : Remediation, use restrictions, dispute with the seller
12 P3×I4 • Historical and soil study before acquisition
• Environmental liability warranties
R-018 Energy price volatility
Cause : Unstable markets, indexed contracts
Consequence : Uncertain profitability, budget variances
12 P3×I4 • Price scenarios in the business plan
• Hedging with fixed-price contracts
R-019 Psychosocial risks and burnout
Cause : Excessive workload, conflicts, lack of recognition, long hours
Consequence : Burnout, absenteeism, resignations, errors
12 P4×I3 • Workload monitoring
• Confidential counsellor and support
R-020 Extreme weather event
Cause : More frequent and intense storms, floods, heatwaves or droughts
Consequence : Damage to installations, business interruption, repair costs
12 P3×I4 • Climate vulnerability assessment of the site
• Weather alert and safety plan
R-021 Dust emissions beyond the site
Cause : Demolition, earthworks, storage of fine materials in dry, windy weather
Consequence : Nuisance to neighbours, complaints, health effects
9 P3×I3 • Damping down and covering stockpiles
• Stop dusty operations in high wind
R-022 Climate change impacts on the project
Cause : More frequent heatwaves, droughts and heavy rain
Consequence : Work stoppages, damage, design to revise
9 P3×I3 • Include climate scenarios in design
• Plan to adapt hours and works
R-023 Structure or roof unsuitable for the installation
Cause : Roof structure strength not checked, old or fragile roof covering
Consequence : Unexpected strengthening, leaks, risk of collapse
9 P3×I3 • Prior structural study
• Protect fragile areas during works
R-024 Fatigue and reduced alertness from night work
Cause : Shifted hours, insufficient sleep, poor lighting
Consequence : Mistakes, accidents, health problems
9 P3×I3 • Shift and break planning
• Adequate lighting everywhere
R-025 Incomplete equipment history and drawings
Cause : Documentation not updated, maintenance software poorly filled in
Consequence : Slow diagnosis, poor decisions, repeated interventions
9 P3×I3 • Systematic work order close-out
• Update drawings after changes
R-026 Noise exceeding permitted limits
Cause : Noisy equipment, night work, no measurements
Consequence : Complaints, enforced stoppage, fines
9 P3×I3 • Quieter equipment and acoustic screens
• Noise measurements and adapted hours
R-027 Delayed grid connection
Cause : Grid operator lead times, insufficient capacity
Consequence : Commissioning postponed, lost revenue
8 P2×I4 • Early connection request
• Schedule aligned with connection date
R-028 Damage to underground utilities
Cause : Incomplete utility maps, digging without prior detection
Consequence : Gas, power or water outage, explosion, injuries
8 P2×I4 • Utility maps and detection before digging
• Hand digging near utilities
R-029 Poor waste management
Cause : Unsorted waste, unapproved contractors, no traceability
Consequence : Fines, producer liability, damaged image
8 P4×I2 • Sorting at source and approved contractors
• Waste register and transfer notes
R-030 Takeover of connected devices
Cause : Cameras, badge readers, sensors or controllers with default passwords
Consequence : Physical or digital intrusion, sabotage, espionage
8 P2×I4 • Change default passwords and keep an inventory
• Separate network for connected devices
R-031 Working in the cold
Cause : Low temperatures, wind, humidity, cold stores
Consequence : Hypothermia, frostbite, muscle problems, falls on icy ground
6 P2×I3 • Suitable clothing and heated rooms
• Organise exposure time
R-032 Exposure to solar ultraviolet radiation
Cause : Long outdoor work in summer without protection
Consequence : Sunburn, long-term skin cancer
6 P2×I3 • Schedule work at less exposed times
• Covering clothing and sunscreen
R-033 Risks for pregnant or breastfeeding workers
Cause : Exposure to substances, strain or night work not adapted
Consequence : Harm to mother or child, non-compliance
6 P2×I3 • Specific assessment once pregnancy is announced
• List of at-risk jobs prepared in advance
R-034 Exposure to dust and fumes
Cause : Cutting, sanding, welding or dry sweeping without extraction
Consequence : Respiratory diseases, irritation
6 P2×I3 • Local extraction and wet methods
• Suitable respiratory protection
R-035 Poor indoor air quality
Cause : Insufficient ventilation, emissive products, dense occupancy
Consequence : Discomfort, headaches, absenteeism, spread of infections
6 P2×I3 • CO2 sensors and ventilation maintenance
• Low-emission materials and products

This example is indicative. Scores and measures must be adapted to your situation and checked by a competent person (prevention advisor, safety coordinator, data protection officer…). It does not replace the risk assessments required by law.

Make it yours in 2 minutes

In Risqure, choose “Power grid works”, adjust a few answers and get this register with owners, due dates, reminders and exports. Free.

Create my register for free

Other examples in this sector