Risk register example: Industrial cleaning
Cleaning tanks, silos or production areas: chemicals, confined spaces, night work and co-activity.
Adapt it to my project (free) Download for Excel (CSV)
Assumptions: Maintenance / facilities · Operation · 10 people · hazardous chemicals, confined spaces (tanks, pits, sewers), work at height (roofs, scaffolding, platforms), night or shift work, site in operation (co-activity with production), lone work, pressure systems, gas, steam.
| Ref. | Risk | Score | Prevention | Protection |
|---|---|---|---|---|
| R-001 | Fall from height
Cause : Missing or removed guardrails, scaffold not inspected, harness misused Consequence : Serious injury or death, investigation, site stoppage |
15 P3×I5 | • Collective protection before any access • Scaffold handover and daily check |
• Rescue-at-height plan |
| R-002 | Electric shock or electrocution
Cause : Work near live parts, incomplete isolation Consequence : Severe burns, death, fire |
15 P3×I5 | • Electrical isolation and voltage check • Up-to-date electrical authorisations |
|
| R-003 | Risks for cleaning staff
Cause : Mixed products, early or late hours, lone work, repetitive movements Consequence : Poisoning, MSDs, assaults |
12 P3×I4 | • Ready-to-use products and no mixing • Ergonomic equipment and daytime cleaning |
|
| R-004 | Fall from a ladder or stepladder
Cause : Ladder used as a workstation, damaged equipment, poor footing Consequence : Fractures, head injury |
12 P3×I4 | • Mobile platforms instead of ladders • Visual check before use |
|
| R-005 | Falling objects from height
Cause : Unsecured materials and tools, no exclusion zone below Consequence : Serious injury to people below, material damage |
12 P3×I4 | • Toe boards, nets and tethered tools |
• Marked exclusion zone below |
| R-006 | Exposure to hazardous chemicals
Cause : Safety data sheets unknown, unsuitable ventilation and PPE Consequence : Poisoning, burns, occupational disease |
12 P3×I4 | • Substitute with a less hazardous product • Inventory, safety data sheets and training |
• Eyewash and emergency kit |
| R-007 | Psychosocial risks and burnout
Cause : Excessive workload, conflicts, lack of recognition, long hours Consequence : Burnout, absenteeism, resignations, errors |
12 P4×I3 | • Workload monitoring |
• Confidential counsellor and support |
| R-008 | Interference between work and ongoing operations
Cause : Unexpected start-up of installations, production flows not stopped Consequence : Accident, production stoppage, damage |
12 P3×I4 | • Work permit issued by the operator |
• Direct link with the control room |
| R-009 | Restart while lockout not properly removed
Cause : Incomplete lockout, poor communication between teams, restart pressure Consequence : Equipment energised or moving with a worker exposed |
10 P2×I5 | • Lockout procedure with personal padlocks • Check before restart |
|
| R-010 | Asphyxiation or poisoning in a confined space
Cause : Atmosphere not tested, no ventilation, no attendant Consequence : Death of the worker and often of the improvised rescuer |
10 P2×I5 | • Entry permit and continuous gas monitoring |
• Outside attendant and rescue equipment |
| R-011 | Unanticipated ageing of installations
Cause : No multi-year replacement plan Consequence : Repeated failures, urgent unbudgeted investments |
9 P3×I3 | • Multi-year investment plan |
• Emergency budget |
| R-012 | Fatigue and reduced alertness from night work
Cause : Shifted hours, insufficient sleep, poor lighting Consequence : Mistakes, accidents, health problems |
9 P3×I3 | • Shift and break planning • Adequate lighting everywhere |
|
| R-013 | Incomplete equipment history and drawings
Cause : Documentation not updated, maintenance software poorly filled in Consequence : Slow diagnosis, poor decisions, repeated interventions |
9 P3×I3 | • Systematic work order close-out |
• Update drawings after changes |
| R-014 | Breakdown of a critical building system
Cause : Heating, ventilation, lifts or generator without preventive maintenance Consequence : Discomfort or interruption for occupants, costly emergency call-outs |
9 P3×I3 | • Preventive maintenance plan by criticality |
• Rapid response contract and critical spares |
| R-015 | Leak of a hazardous product or gas
Cause : Faulty seal, corrosion, handling error during transfer Consequence : Poisoning, fire, pollution |
8 P2×I4 | • Inspect transfer and storage equipment |
• Bunding, detectors and spill kits |
| R-016 | Burn from hot fluid or corrosive product
Cause : Opening a pressurised or hot circuit, splash, no PPE Consequence : Serious burns, eye injury |
8 P2×I4 | • Drain, cool and depressurise before opening |
• Face shield, gloves and safety shower |
| R-017 | Assault on a security guard
Cause : Lone interventions, night patrols, intrusions Consequence : Injuries, trauma |
8 P2×I4 | • Intervention rules and remote verification |
• Lone-worker alert device |
| R-018 | Accident during work on a plant roof
Cause : Roof equipment without safe access, no guardrails Consequence : Fall from height |
8 P2×I4 | • Permanent safe access and walkways • Roof access permit |
|
| R-019 | Historical soil contamination found on an existing site
Cause : Undocumented past activities, forgotten underground tanks Consequence : Remediation, use restrictions, dispute with the seller |
8 P2×I4 | • Historical and soil study before acquisition |
• Environmental liability warranties |
| R-020 | Unexpected start-up during maintenance
Cause : Residual energy, remote control, controller restarting Consequence : Crushing, electric shock, entanglement |
8 P2×I4 | • Isolate all energy sources • Lockout sheets per machine |
|
| R-021 | Missed statutory periodic inspections
Cause : Deadlines not tracked (lifts, electrical, fire, lifting) Consequence : Non-compliance, liability in case of accident, insurance refusal |
8 P2×I4 | • Statutory inspection calendar |
• Track closure of findings |
| R-022 | Legionnaires’ disease from water systems
Cause : Stagnant or lukewarm water in pipework, poorly maintained cooling towers Consequence : Cases of Legionnaires’ disease among occupants, operator liability |
8 P2×I4 | • Water system management plan |
• Procedure in case of positive results |
| R-023 | Takeover of connected devices
Cause : Cameras, badge readers, sensors or controllers with default passwords Consequence : Physical or digital intrusion, sabotage, espionage |
8 P2×I4 | • Change default passwords and keep an inventory • Separate network for connected devices |
|
| R-024 | Refrigerant leak
Cause : Poorly maintained air-conditioning or refrigeration systems Consequence : Environmental harm, non-compliance, breakdown |
6 P2×I3 | • Statutory leak checks |
• Service log and refrigerant recovery |
| R-025 | Assault on a lone or night worker
Cause : Working alone in the evening or at night, handling valuables, isolated areas Consequence : Injuries, trauma |
6 P2×I3 | • Lighting, access control and closing procedure |
• Lone-worker alarm device |
| R-026 | Poor waste management
Cause : Unsorted waste, unapproved contractors, no traceability Consequence : Fines, producer liability, damaged image |
6 P3×I2 | • Sorting at source and approved contractors |
• Waste register and transfer notes |
| R-027 | Accidental oil spill
Cause : Refuelling machines, tank leak, burst hydraulic hose Consequence : Soil and water pollution, costly clean-up |
6 P2×I3 | • Sealed refuelling area |
• Spill kit and response procedure |
| R-028 | Failure to sort and trace waste
Cause : Mixed skips, untraced disposal, no waste register Consequence : Fines, liability for fly-tipping |
6 P2×I3 | • Separate skips and signage • Register and transfer notes kept |
|
| R-029 | Exposure to dust and fumes
Cause : Cutting, sanding, welding or dry sweeping without extraction Consequence : Respiratory diseases, irritation |
6 P2×I3 | • Local extraction and wet methods |
• Suitable respiratory protection |
| R-030 | Occupational skin disease
Cause : Repeated contact with water, detergents, cement or solvents Consequence : Eczema, skin allergies, unfitness for work |
6 P2×I3 | • Substitute irritating products |
• Suitable gloves and skin care |
| R-031 | Noise exceeding permitted limits
Cause : Noisy equipment, night work, no measurements Consequence : Complaints, enforced stoppage, fines |
6 P2×I3 | • Quieter equipment and acoustic screens |
• Noise measurements and adapted hours |
| R-032 | Risks for pregnant or breastfeeding workers
Cause : Exposure to substances, strain or night work not adapted Consequence : Harm to mother or child, non-compliance |
6 P2×I3 | • Specific assessment once pregnancy is announced • List of at-risk jobs prepared in advance |
This example is indicative. Scores and measures must be adapted to your situation and checked by a competent person (prevention advisor, safety coordinator, data protection officer…). It does not replace the risk assessments required by law.
In Risqure, choose “Industrial cleaning”, adjust a few answers and get this register with owners, due dates, reminders and exports. Free.