Risk register example: Chemical storage facility
Storing hazardous products: compatibility, retention, fire and explosion risks, permits.
Adapt it to my project (free) Download for Excel (CSV)
Assumptions: Industry / manufacturing · Planning / design · 10 people · hazardous chemicals, pressure systems, gas, steam, hot work (welding, cutting, grinding), site in operation (co-activity with production), permits or authorisations required, near water or flood-prone area, protected natural area or sensitive environment.
| Ref. | Risk | Score | Prevention | Protection |
|---|---|---|---|---|
| R-001 | Fire caused by hot work
Cause : Sparks near combustible materials, no fire watch after work Consequence : Building fire, injuries, business interruption |
20 P4×I5 | • Hot work permit |
• Two-hour fire watch after work |
| R-002 | Electric shock or electrocution
Cause : Work near live parts, incomplete isolation Consequence : Severe burns, death, fire |
15 P3×I5 | • Electrical isolation and voltage check • Up-to-date electrical authorisations |
|
| R-003 | Pollution of a watercourse or sensitive environment
Cause : Run-off, fuel stored without bunding, accidental release Consequence : Harm to wildlife and plants, sanctions, costly restoration |
12 P3×I4 | • Bunding, refuelling area and settling ponds |
• Spill kits and alert procedure |
| R-004 | Exposure to hazardous chemicals
Cause : Safety data sheets unknown, unsuitable ventilation and PPE Consequence : Poisoning, burns, occupational disease |
12 P3×I4 | • Substitute with a less hazardous product • Inventory, safety data sheets and training |
• Eyewash and emergency kit |
| R-005 | Permit granted late or refused
Cause : Incomplete application, underestimated processing times, third-party appeals Consequence : Delayed start, idle teams, project to be redesigned |
12 P4×I3 | • Permit back-schedule • Pre-application meeting with authorities |
|
| R-006 | Interference between work and ongoing operations
Cause : Unexpected start-up of installations, production flows not stopped Consequence : Accident, production stoppage, damage |
12 P3×I4 | • Work permit issued by the operator |
• Direct link with the control room |
| R-007 | Unplanned production stoppage
Cause : Critical equipment failure, no spare parts Consequence : Late orders, operating losses |
12 P3×I4 | • Equipment criticality analysis |
• Critical spare parts stock |
| R-008 | Accident during an urgent breakdown repair
Cause : Pressure to restart quickly, risk assessment skipped Consequence : Serious injury, worse breakdown |
12 P3×I4 | • Quick risk check before each repair • Stop-work authority backed by management |
|
| R-009 | Restart while lockout not properly removed
Cause : Incomplete lockout, poor communication between teams, restart pressure Consequence : Equipment energised or moving with a worker exposed |
10 P2×I5 | • Lockout procedure with personal padlocks • Check before restart |
|
| R-010 | Explosion or leak of pressure equipment or gas
Cause : Uninspected equipment, faulty fittings, mishandling Consequence : Burns, serious injuries, fire |
10 P2×I5 | • Statutory inspections and maintenance |
• Gas detection and emergency procedure |
| R-011 | Product recall
Cause : Manufacturing defect, contamination, labelling error Consequence : Withdrawal costs, loss of customers, brand damage |
10 P2×I5 | • Quality checks at critical steps |
• Batch traceability and tested recall procedure |
| R-012 | Regulatory change during the project
Cause : New standard, law or permit requirement adopted before completion Consequence : Studies and works to redo, extra costs, delay |
9 P3×I3 | • Project-specific regulatory watch |
• Change-in-law clause |
| R-013 | Non-conforming product delivered
Cause : Process drift, insufficient inspections Consequence : Claims, recalls, loss of customers |
9 P3×I3 | • Control plan and statistical monitoring |
• Batch traceability |
| R-014 | Raw material shortage
Cause : Tight markets, failing supplier Consequence : Reduced production, higher costs |
9 P3×I3 | • Dual sourcing of critical materials |
• Sized safety stock |
| R-015 | Incomplete equipment history and drawings
Cause : Documentation not updated, maintenance software poorly filled in Consequence : Slow diagnosis, poor decisions, repeated interventions |
9 P3×I3 | • Systematic work order close-out |
• Update drawings after changes |
| R-016 | Molten metal or spark projection
Cause : Casting, welding, thermal cutting without suitable protection Consequence : Serious burns, fire |
8 P2×I4 | • Protective screens and marked zones |
• Flame-resistant clothing and suitable equipment |
| R-017 | Leak of a hazardous product or gas
Cause : Faulty seal, corrosion, handling error during transfer Consequence : Poisoning, fire, pollution |
8 P2×I4 | • Inspect transfer and storage equipment |
• Bunding, detectors and spill kits |
| R-018 | Burn from hot fluid or corrosive product
Cause : Opening a pressurised or hot circuit, splash, no PPE Consequence : Serious burns, eye injury |
8 P2×I4 | • Drain, cool and depressurise before opening |
• Face shield, gloves and safety shower |
| R-019 | Operating without an up-to-date environmental permit
Cause : Undeclared change of activity, operating conditions not met Consequence : Formal notice, fine, suspension of activity |
8 P2×I4 | • Register of permit obligations • Regulatory check before any modification |
|
| R-020 | Exposure to carcinogens
Cause : Welding fumes, wood dust, solvents, silica Consequence : Occupational cancers, employer liability |
8 P2×I4 | • Substitution and local exhaust • Exposure measurement and health surveillance |
|
| R-021 | Non-compliance with chemical registration and restriction rules
Cause : Substance subject to authorisation or restriction used unknowingly Consequence : Forced stop, reformulation, penalties |
8 P2×I4 | • Watch substances of concern |
• Early substitution plan |
| R-022 | Historical soil contamination found on an existing site
Cause : Undocumented past activities, forgotten underground tanks Consequence : Remediation, use restrictions, dispute with the seller |
8 P2×I4 | • Historical and soil study before acquisition |
• Environmental liability warranties |
| R-023 | Combustible dust explosion
Cause : Build-up of wood, flour, sugar or metal dust, ignition source Consequence : Explosion, fire, collapse |
8 P2×I4 | • Regular cleaning and dust extraction |
• Venting and isolation of equipment |
| R-024 | Incompatible products stored together
Cause : Acids and bases, oxidisers and flammables side by side Consequence : Dangerous reaction, fire, toxic gases |
8 P2×I4 | • Storage plan by hazard class |
• Separate bunds and detection |
| R-025 | Unexpected start-up during maintenance
Cause : Residual energy, remote control, controller restarting Consequence : Crushing, electric shock, entanglement |
8 P2×I4 | • Isolate all energy sources • Lockout sheets per machine |
|
| R-026 | Discharge limits exceeded
Cause : Saturated treatment plant, process drift Consequence : Formal notice, fine, administrative shutdown |
8 P2×I4 | • Self-monitoring and threshold alarms |
• Output reduction procedure |
| R-027 | Extreme weather event
Cause : More frequent and intense storms, floods, heatwaves or droughts Consequence : Damage to installations, business interruption, repair costs |
8 P2×I4 | • Climate vulnerability assessment of the site |
• Weather alert and safety plan |
| R-028 | Site flooding
Cause : Flood-prone area, heavy rain, rising groundwater Consequence : Damage to works and equipment, extended stoppage |
8 P2×I4 | • Weather watch and flood alerts |
• Store equipment outside flood zone |
| R-029 | Non-compliant safety data sheets and labelling
Cause : Products without up-to-date sheets, misclassified mixtures, missing labels Consequence : Poor prevention, penalties, customer refusal |
6 P2×I3 | • Product inventory with current sheets • Label secondary containers |
|
| R-030 | Poor management of hazardous waste
Cause : Mixed waste, non-compliant storage, unauthorised disposal route Consequence : Pollution, penalties, producer liability |
6 P2×I3 | • Sorting, labelling and bunded storage • Licensed collectors and traceability |
|
| R-031 | Accidental oil spill
Cause : Refuelling machines, tank leak, burst hydraulic hose Consequence : Soil and water pollution, costly clean-up |
6 P2×I3 | • Sealed refuelling area |
• Spill kit and response procedure |
| R-032 | Failure to sort and trace waste
Cause : Mixed skips, untraced disposal, no waste register Consequence : Fines, liability for fly-tipping |
6 P2×I3 | • Separate skips and signage • Register and transfer notes kept |
|
| R-033 | Exposure to dust and fumes
Cause : Cutting, sanding, welding or dry sweeping without extraction Consequence : Respiratory diseases, irritation |
6 P2×I3 | • Local extraction and wet methods |
• Suitable respiratory protection |
| R-034 | Occupational skin disease
Cause : Repeated contact with water, detergents, cement or solvents Consequence : Eczema, skin allergies, unfitness for work |
6 P2×I3 | • Substitute irritating products |
• Suitable gloves and skin care |
| R-035 | Runaway chemical reaction
Cause : Dosing error, cooling failure, contamination Consequence : Explosion, toxic release, casualties |
5 P1×I5 | • Process safety study |
• Relief vents and internal emergency plan |
This example is indicative. Scores and measures must be adapted to your situation and checked by a competent person (prevention advisor, safety coordinator, data protection officer…). It does not replace the risk assessments required by law.