Risk register example: Electronic patient record
Deploying a patient record system: health data, availability, migration and adoption by care staff.
Adapt it to my project (free) Download for Excel (CSV)
Assumptions: Healthcare · Planning / design · 8 people · personal data processed, service must be available 24/7, data migration, integration with existing systems, cloud or saas services.
| Ref. | Risk | Score | Prevention | Protection |
|---|---|---|---|---|
| R-001 | Exploitation of an unpatched vulnerability
Cause : Internet-facing software and devices not updated, incomplete asset inventory Consequence : Intrusion, data theft, service outage |
16 P4×I4 | • Inventory of exposed assets and priority patching • Regular vulnerability scanning |
|
| R-002 | Compromise through a supplier or third-party software
Cause : Provider with broad access, tampered software update, poorly assessed dependency Consequence : Intrusion via the supply chain, data leak, business interruption |
12 P3×I4 | • Security assessment of critical suppliers • Limited and logged supplier access |
|
| R-003 | GDPR non-compliance
Cause : Personal data processed without legal basis, record or information of data subjects Consequence : Data protection authority fine, complaints |
12 P3×I4 | • Record of processing and impact assessment • Data minimisation and retention periods |
|
| R-004 | Extended service outage
Cause : Hosting failure, failed update, no redundancy Consequence : Users blocked, financial losses, contractual penalties |
12 P3×I4 | • Monitoring and automatic alerts |
• Recovery plan and redundancy |
| R-005 | Healthcare-associated infection
Cause : Poor hand hygiene, protocols not followed Consequence : Patient complications, investigation |
12 P3×I4 | • Hand hygiene audits |
• Case reporting and analysis |
| R-006 | Shortage of care staff
Cause : Hiring difficulties, absenteeism Consequence : Overload, lower quality and safety of care |
12 P4×I3 | • Internal relief pool |
• Minimum safe staffing levels |
| R-007 | Medication error
Cause : Unclear prescriptions, interruptions during preparation Consequence : Serious adverse effect for the patient |
12 P3×I4 | • Double check for high-risk drugs • Interruption-free preparation area |
|
| R-008 | Patient fall
Cause : Reduced mobility, medication, cluttered environment, call bell out of reach Consequence : Fracture, longer stay, complaint from the family |
12 P3×I4 | • Fall risk assessment on admission |
• Review every fall |
| R-009 | Burnout among care staff
Cause : Emotional load, shift work, chronic understaffing Consequence : Absenteeism, resignations, lower quality of care |
12 P4×I3 | • Stable rotas and protected rest |
• Debriefing spaces and psychological support |
| R-010 | Diagnostic error or delay
Cause : Workload, tests not followed up, results not passed on, cognitive bias Consequence : Wrong or late treatment, deterioration, complaint |
12 P3×I4 | • Systematic tracking of pending results • Second opinion for complex cases |
|
| R-011 | Ransomware attack
Cause : Unpatched computers, backups reachable from the network, no segmentation Consequence : Systems down, data lost, ransom demanded |
10 P2×I5 | • Patching and endpoint protection |
• Tested offline backups |
| R-012 | Wrong-site or wrong-patient surgery
Cause : No checklist, site marking omitted, team change Consequence : Operation on the wrong side or patient |
10 P2×I5 | • Surgical safety checklist • Surgical site marking |
|
| R-013 | Sepsis not recognised in time
Cause : Warning signs not monitored, no early warning score, late escalation Consequence : Septic shock, avoidable death |
10 P2×I5 | • Early warning score and sepsis protocol |
• Rapid response team |
| R-014 | Hospital-acquired venous thrombosis
Cause : Risk assessment not done, prophylaxis missed, prolonged immobility Consequence : Pulmonary embolism, death |
10 P2×I5 | • Thrombosis risk assessment on admission • Early mobilisation |
|
| R-015 | Account takeover without multi-factor authentication
Cause : Reused or stolen password, email and online tools protected by a single factor Consequence : Impersonation, data access, fraud sent from a legitimate account |
9 P3×I3 | • Mandatory multi-factor authentication |
• Alerts on unusual sign-ins |
| R-016 | Backups that cannot be restored
Cause : Backups never tested, incomplete or encrypted by the attacker Consequence : Permanent data loss after an incident |
9 P3×I3 | • Quarterly restore test |
• Offline or immutable copy |
| R-017 | Incomplete or incorrect data migration
Cause : Inconsistent source data, poorly defined transformation rules Consequence : Errors in production, loss of user trust |
9 P3×I3 | • Data cleansing and dry runs |
• Reconciliation checks and rollback |
| R-018 | Violence against healthcare staff
Cause : Waiting, pain, behavioural disorders, alcohol or drug use Consequence : Injuries, post-traumatic stress, absenteeism |
9 P3×I3 | • De-escalation training |
• Emergency alarm and post-incident support |
| R-019 | Data leak through human error
Cause : Wrong recipient, wrong attachment, overly open sharing link Consequence : Data breach to notify, loss of trust |
9 P3×I3 | • Short, repeated awareness sessions • Send delay and external-recipient warning |
|
| R-020 | Uncontrolled use of generative AI tools
Cause : Staff pasting confidential or personal data into public tools Consequence : Information leak, GDPR non-compliance, loss of trade secrets |
9 P3×I3 | • AI acceptable-use policy • Enterprise AI tool with contractual commitments |
|
| R-021 | Lack of in-house digital skills
Cause : Reliance on one person or a provider, insufficient training Consequence : Stalled projects, poor use of tools, security risks |
9 P3×I3 | • Targeted training plan |
• Documentation and support contract |
| R-022 | Blood exposure incident
Cause : Needlestick or cut with a contaminated item, full containers, recapping Consequence : Infection risk, anxiety, medical follow-up |
9 P3×I3 | • Safety devices and containers within reach |
• Displayed procedure |
| R-023 | Information lost during handovers
Cause : Unstructured verbal handover, interruptions, incomplete records Consequence : Missed care, treatment errors |
9 P3×I3 | • Structured handover method • Protected handover time |
|
| R-024 | Medication reconciliation error at admission or discharge
Cause : Usual treatment unknown, conflicting prescriptions Consequence : Treatment omitted or duplicated, adverse effects |
9 P3×I3 | • Systematic medication history |
• Discharge letter with updated treatment |
| R-025 | Shortage of essential medicines or devices
Cause : Manufacturer stock-out, higher demand, single supplier Consequence : Treatments postponed or substituted, risk of error |
9 P3×I3 | • Shortage watch and safety stock |
• Validated substitution protocols |
| R-026 | No cyber incident response plan
Cause : Roles undefined, emergency contacts unknown, notification duties ignored Consequence : Slow reaction, greater damage, penalties for late notification |
8 P2×I4 | • One-page response plan and emergency contacts • Annual cyber crisis exercise |
|
| R-027 | Breach of health data confidentiality
Cause : Records consulted without need, visible screens, insecure exchanges Consequence : Penalties, complaints, loss of patient trust |
8 P2×I4 | • Role-based access and audit trails • Secure health messaging |
|
| R-028 | Electronic health record unavailable
Cause : Outage, maintenance, cyberattack Consequence : No access to history and treatments, delays and errors |
8 P2×I4 | • Downtime procedure and backup printouts • Re-entry and checks after recovery |
|
| R-029 | Cloud service misconfiguration
Cause : Storage left public, overly broad rights, logging disabled Consequence : Data exposed on the internet, large-scale leak |
8 P2×I4 | • Review of sharing and security settings • Documented baseline configuration |
|
| R-030 | Outage at a major digital provider
Cause : Incident at a host, software vendor or operator many services depend on Consequence : Several tools down at once, business blocked |
8 P2×I4 | • Map critical digital dependencies • Degraded operating mode |
|
| R-031 | Backup power failure
Cause : Generator or UPS not tested, insufficient fuel Consequence : Vital equipment stops during a power cut |
8 P2×I4 | • Regular load tests |
• Fuel reserve and supply contract |
| R-032 | Malicious act by an employee or former employee
Cause : Access not removed on departure, excessive rights, labour dispute Consequence : Data theft or destruction, sabotage |
8 P2×I4 | • Leaver procedure with same-day access removal • Six-monthly access review |
|
| R-033 | Non-compliance with the EU AI Act
Cause : High-risk AI system not identified, insufficient transparency, missing documentation Consequence : Fines, system withdrawn, reputational damage |
8 P2×I4 | • Inventory and classification of AI uses • User information and technical documentation |
|
| R-034 | Failure to meet NIS2 obligations
Cause : Entity in scope not registered, missing risk-management measures, incidents not notified Consequence : Fines, management liability, regulator inspection |
8 P2×I4 | • Scope check and registration • Cybersecurity action plan tracked by management |
|
| R-035 | Unregulated data transfer outside the EU
Cause : Provider or sub-processor outside the EU, no safeguards Consequence : GDPR non-compliance, need to change tools |
6 P2×I3 | • Check location and safeguards • Prefer EU hosting |
This example is indicative. Scores and measures must be adapted to your situation and checked by a competent person (prevention advisor, safety coordinator, data protection officer…). It does not replace the risk assessments required by law.